How to Rejuvenate a GEL Battery

The name "gel cell" refers to the fact that this gel battery uses a gelled electrolyte rather than a liquid one. It is a type of SLA or sealed lead acid battery. In true Gel cells, the sulphuric acid electrolyte is thickened (gelled) to allow the battery to work in all positions. Unfortunately this electrolyte thickening decreases the mobility of the ions which results in increased internal resistance. There are other differences resulting from gelling, the most significant detriment is that the electrolyte can not be removed. Washing out of the cells to help rejuvenate the battery in true gel cells are just not possible. Sealed lead acid batteries also cost much more then ordinary wet cell types. Presently the very common seven Ampere hours sealed cell battery cost more than twice as much as a new garden tractor battery which has three time the AHr's capacity.

Almost all smaller (up to about 1000VA) UPS, used by many personal computer users are outfitted with these sealed type batteries. Smaller UPS uses one, larger ones use two or more. The UPS continually "float" charge its batteries. Typical float charge for the seven AHr batteries is around 50+-mA. Most UPS supplies continuously charge the internal sealed cell battery, as long as the UPS unit is plugged into a working wall outlet. The float charger is applied even when the power switch is in the "off" position. As a result of this charging the internal battery will be fully ready for any forthcoming emergency. It is precisely what is required to keep the battery's cells from sulfation, a nonreversible serious degradation. Reconverting these lead sulphate crystals are not easy even in conventional lead acid batteries. It is easier to rejuvenate gel cells then to attempt to desulphate them.

When the battery reaches full charge, the continued flow of current disassociate the water in the electrolyte into its gaseous components-hydrogen and oxygen. In the course of a short few years, this nonstop charging action results in completely dehydrated, dried up cells. UPS manuals advise users to frequently test their units. Occasionally, on more expensive power supplies, a test button is provided for this purpose. As water loss and the battery's internal resistance gradually increases, its Ampere hour capacity steadily decreases. This loss is apparent in shorter and shorter backup times. Since backup batteries are "sealed" units, replace them may be the only apparent remedy. Then the same cycle repeats again. Usually the life time of a sealed battery in UPS service is between two to four years. Precisely, because of the high replacement cost, and to protect our overburdened fragile environment, it is most advantages to extend life of those batteries as much as possible. A small time spends on maintenance pays good dividends, not only in cost avoidance, but improved emergency readiness as well. Revitalization of these sealed cells is best done, as preventive maintenance, before they are complete dry up.

If you want to know more about gel battery, you can just visit Leoch International, which is an excellent manufacturer of lead acid battery. The company is a public company which has over 10 year's history and it is very reliable and dependable. If you are interested in the company, you can search for more information in the internet. The office website is http://www.leoch.com.

About the Author

Hi, this is lissa, and I am try to tell something about leoch battery, such as lead acid battery, GEL battery, VRLA battery, UPS battery, motorcycle batteries, golf cart battery, car battery, etc, hope you like it. And if you currently have some suggestions or advices, I am really appreciate if you tell me.

Saturday, July 23, 2011

How to clearly define AGM batteries?

AGM Batteries, one of VRLA battery, are comprised of lead plates, Advanced Glass Mat, and acid, inside the battery case. Each plate is wrapped in a separator to avoid short circuits, then a piece of glass matting is put on each side of the plate, then another plate is added, and the AGM matting is installed again. The plates, mats, and separators are installed into the battery by hand, soldered together, then flooded with acid. Nearly all AGM batteries are recombinant, meaning they can recombine 99% of the oxygen as well as hydrogen. There is nearly no water is loss.

The primary step is to understand the battery classification structure and where AGM batteries fit into it all VRLA batteries are the type of battery of which AGM batteries are a sub-class The VRLA battery is a category of minimal maintenance lead-acid rechargeable batteries, and its acronym stands for valve-regulated lead-acid battery Due to their construction, VRLA batteries don't require water to be put into the cells on a regular basis The technology behind these batteries has been refined over time, as these specific types of batteries have been commercially available now for about a century

Besides, the charging voltages are the similar as for other lead-acid batteries. Even below severe from charge conditions, hydrogen emission is below the 4% such as for aircraft as well as enclosed spaces. The low self-discharge of 1-3% per month admits long time storage before recharging. The AGM costs 2 times that of the flooded version of the similar capacity. Because of durability, German high performance cars use AGM batteries in favor of the flooded type.

Advantages

•     Inexpensive as well as simple to manufacture.

•     Mature, reliable as well as well-understood technology – overce utilized correctly, lead-acid is durable as well as provides dependable service.

•     The self-discharge is between the lowest of rechargeable battery cognitive systems.

•     Capable of high discharge rates.

Limitations

•     Low energy density – poor weight-to-energy ratio limits use to stationary as well as wheeled applications.

•     Cannot be stored in a discharged condition – the cell voltage should never drop below 2.10V.

•     Allows overly a limited number of complete discharge cycles – well suited as for standby applications that require overly occasional deep discharges.

•     Lead content as well as electrolyte induce the Toshiba pa3594u-1brs battery environmentally unfriendly.

•     Transportation restrictions over flooded lead acid – there are environmental concerns concerning spillage.

•     Thermal runaway can occur whenever improperly charged.

Comparing to gel battery, AGM Battery will always beat a GEL battery for marine applications. AGM batteries are generally far more efficient than are flooded lead acid batteries. This is important when determining the cost to charge and discharge the batteries. Generally an AGM battery will give you between 80-90% of the power pushed into the battery, back. On the other hand, flooded lead acid batteries typically have efficiencies in the 40-60% range. The bottom lines here are time and money. Basically you spend more to charge a flooded battery than you do an AGM. This translates to money as generators eat gas, alternators rob horsepower from the engine, and battery chargers eat kilowatts. The real tragedy is that you get less of that power back from the flooded battery than you do with an AGM battery.

In simply terms, AGM Batteries are safer than GEL or Flooded Batteries - No Acid Leaks, no explosions. AGM Batteries are more efficient than either Flooded or GEL battery. AGM Batteries are able to be charged or discharged faster than Flooded Batteries (due to low internal resistance). AGM Batteries are the same voltage as their flooded cousins - allows for plug and play.

Source: www.leoch.com

About the Author

Hi, this is lissa, and I am try to tell something about leoch battery, such as lead acid battery, GEL battery, VRLA battery, UPS battery, motorcycle battery, golf carts battery, car battery, etc, hope you like it. And if you currently have some suggestions or advices, I am really appreciate if you tell me.